GFC-IIA
| WORLD # |
Description |
OEM # |
| 7000.9012 |
Generator Field Control Regulator |
7000.9012 |
| 7000.9013 |
GFC IIA Cable Assembly* |
7000.9013 |
| 7000.9016 |
GFC IIA Box Assembly • |
7000.9016 |
| 7000.9021 |
GFC IIA Knob Protection Bracket** |
7000.9021 |
| 7000.9022 |
GFC IIA Installation Kit ~ |
7000.9022 |
*4'
cable used to interface GFC IIA regulator to system. Complete
with 24 pin connector.
• Heavy duty steel enclosure used to mount GFC IIA on site or in control
cab. Can also be used with GFC, GFC II, lSSD-1, GMB-A and GMB-B.
** In some areas of the country, UL requires this cover to be used. The
bracket protects all of the external potentiometer knobs from accidental
bumping once the GFC IIA is adjusted properly.
~ Kit includes all external resistors, capacitors and relays necessary
to interface GFC IIA or other generator field control regulators to a motor-generator
set. |
GFC IIA replaces U.S. Elevator (Varitron) SSD1, Elevator Industries
GMB (Model A), Reliable Elevator GFC, GFCII. Also replaces E-I
GMB (Model B) with minor wiring change.
NOTE: Also used in variable voltage controllers made by numerous
regional companies, such as, Virginia Controls, Vertitron, Mid-American,
Century, etc. See full specification below and an expanded data
sheet.

Supplies generator shunt field, brake excitations. Provides consistent,
smooth, stepless acceleration, and stopping functions, and is adaptable
to all new or modernized elevator installations up to 350 FPM.
Incorporates the following independent controls:
• High speed
• Acceleration
•
Deceleration – one floor run
•
Deceleration – multi-floor run
• Approach speed
• Level speed
• Relevel speed
• Motor field weakening
Solid state design. Furnishes built-in protection from loss of
motor field.
All units undergo high-temp environmental testing and burn-in to
minimize problems caused by infant component mortality after installation
in the field. (Box and cable assembly not included.) Technical Specifications:
Supply: 220 - 240 VAC - 60Hz, single phase
Input: Dry contact closure or transistor drive
Output: Generator field: 5A @ 140 VDC max @ 40 - 150 0HMS
Hoist motor field: 8A @ 200 VDC max @ 30 - 150 0HMS
Brake: 3A @ 200 VDC mac @100 - 500 OHMS
Soft stop: 30 MA @ 35 VDC
Protection:
Generator: 16A
Hoist motor field: 15A
Brake: 3A
Generator field excitation range, ADJ O to:
High: 140 VDC
Intermediate: 120 VDC
High level: 50 VDC
Level: 10 VDC
Relevel: 20 VDC
Acceleration: ADJ .05 - 4.0 seconds
Deceleration: ADJ 0.5 - 4.0 seconds
Physical:
Size: 6” x 9 3/4” x 5”
OP temperature: -32° to +120° (F)
Accessories for GFC IIA
7000.9013 4’ cable w/connector
7000.9016 Box for mounting
7000.9022 R/C interface kit
Connector: Cinch S3324CCE
|